HACH QP1680 High-Temperature TOC Laboratory Analyzer, with auto sampler, 96 positions PN.LPV448.99.00501
HACH QP1680 High-Temperature TOC Laboratory Analyzer, with auto sampler, 96 positions PN.LPV448.99.00501
无法加载取货服务可用情况
The QP1680 Analyzer measures Total Organic Carbon (TOC) and Total Nitrogen (TNb) in one sample.
The QP1680 is available as a combined TOC and TNb analyzer or for the individual parameters TOC or TNb.
The most important features include:
• Direct sample injection eliminates sample contact with valves and the built-in injection syringe, which minimizes the risk of sample carry-over.
• Large diameter sample aspiration tubing can handle particles up to 800 µm, expanding possible applications and reducing clogging.
• Integrated stirrer for each sample position homogenizes particle-containing samples before injection.
• Small footprint with integrated 65-position auto-sampler requires less space in the laboratory (an auto-sampler with 96 positions is also available as an alternative).
• Simple operation, data analysis and system diagnosis thanks to an intuitive software package.
Specifications
Technical Attributes
Ambient Temperature | -20 - 60 °C (-4 - 140 °F) |
Analysis time | Approx. 3 minutes |
Dimensions | 440 x 380 x 700 mm / 17.3 x 15 x 27.6 in. (H x W x D) |
Gas consumption | 150 mL/min* *Sample preparation for NPOC determination requires additional 300-350 mL/min. |
Gas specifications | Oxygen or synthetic air: minimum 99.998% (4.8) at 3 - 10 bar |
Lower Limit of Detection (LOD) | TC, TOC, NPOC: 50 µg/L |
Measurement Method | NDIR (non-dispersive Infrared Detection) |
Model | QP1680-TOC |
Norms and Standards | TOC / NPOC: ASTM D7573, EN 1484, EPA 415.1, EPA 9060A, ISO 8245, SM 5310B, NEN-ISO 20236 |
Number of sample positions | 96 |
Operating Conditions | 20 - 30 °C (68 - 86 °F); 20 - 80% relative humidity (non-condensing) |
Oxidation Method | Catalytic combustion at 680 °C |
Parameter | TOC |
Pollution Degree | 2 |
Power | Analyzer: 750 W max. PC: 90 W max. Monitor: 100 W max. |
Power Supply | Analyzer: 100 - 240 VAC, 50/60 Hz, 16 A, with protective grounding PC: 100 - 240 VAC, 50/60 Hz, 1.6 A, with protective grounding Monitor: 100 - 240 VAC, 50/60 Hz, 1.6 A, with protective grounding |
Range | TC, TIC, NPOC: 0 - 30000 mg/L |
Repeatability | Up to 10 mg/L TC, TIC, NPOC, TN: < 5% > 10 mg/L TC, TIC, NPOC, TN: < 2% |
Sample Volume | 10 - 1000 µL |
Temperature | Furnace temperature max. 1050 °C (1922 °F) (depending on configuration) |
Warranty | 12 months |
Weight | Approx. 31 kg (68.3 lbs) |
What's included? | TOC Instrument Sample tray with 96 positions for 24 mL vials Glass sample vials 24 mL (100 pcs) USB 2.0 cable A-B Set of tubing PTFE blue-stripe 1/8" OD length 2 m including nut & ferrule Reagent container with screwcap for UPW, Acid and Waste Power cord USB storage device with software, test results and Full User Manual Printed User Manual |