跳至产品信息
1 / 1

HACH

HACH Nonionic Surfactants TNTplus Vial Test, LR (0.2-6.0 mg/L as Triton X-100), 25 Tests PN.TNT875

HACH Nonionic Surfactants TNTplus Vial Test, LR (0.2-6.0 mg/L as Triton X-100), 25 Tests PN.TNT875

常规价格 ¥4,130.00 CNY
常规价格 ¥4,956.00 CNY 促销价 ¥4,130.00 CNY
促销 售罄

Note: You must order 12 pieces or multiples of 12. No other quantities will be accepted.

 

Expert Low Range Nonionic Surfactants test made simple.

Nonionic Surfactants TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. For determination of lower concentrations of Nonionic Surfactants by the TBPE method, calibrated with Triton X-100. Traditional surfactants measurement has often involved time consuming handling steps, requiring expensive high end instrumentation or the use of large amounts of toxic chemistries. With Surfactants TNTplus reagents, simply add sample and included reagents to the vial, shake the vial for a defined period of time and insert into your Hach spectrophotometer! The Direct Read Technology will provide your Surfactants results in mg/L! No more cleaning glassware, dealing with large amounts of toxic waste, and worrying about human errors.

Upgrade from traditional Surfactants methods to TNTplus Surfactants reagents today!

25 Nonionic Surfactants vials per box.

 

Benefits

Easy and safe handling

The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.

No reagent blank necessary

The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!

Automatic method detection

The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.

Documented shelf life and COA

New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.

 

Specifications

 

Technical Attributes

Instrument DR3900, DR6000, DR1900, DR2800, DR3800, DR5000
Method Name TBPE
Method Number 10275
Number of tests 25
Parameter Surfactants, Nonionic
Platform TNT plus™
Range 0.2 - 6.0 mg/L as Triton x 100
Storage Conditions 15 - 25 °C
查看完整详细信息