HACH
HACH IntelliCAL ISENH418101 Ammonium (NH₄⁺) Ion Selective Electrode (ISE) with Calibration Reagents Pack PN. ISENH4181AP
HACH IntelliCAL ISENH418101 Ammonium (NH₄⁺) Ion Selective Electrode (ISE) with Calibration Reagents Pack PN. ISENH4181AP
无法加载取货服务可用情况
* Please consult before ordering
The IntelliCALⓇ Ammonium ISE Analysis Package contains all you need to start measuring ammonium (NH4+) with your HQD meter instrument: The IntelliCALⓇ ISENH4181 Ammonium ISE with 1 m cable, 500 mL bottles of 10 mg/L and 100 mg/L of Hach nitrogen-ammonia standard solutions, pack of 100 Hach ammonium ionic strength adjustor (ISA) Powder Pillows.
Benefits
Utilizes a unique solid-state sensor technology that eliminates costly membrane replacements.
Traditional PVC-membrane ISEs require membrane replacement every 2-3 months. The IntelliCAL ISENH4181 Ammonium ISE’s unique solid-state sensor technology eliminates the need for frequent membrane replacement by using a solid gel ion exchange behind the ion-selective membrane versus the liquid ion exchange used in most ISEs. This design allows users to get up to 2 years of life from their ISE without membrane replacement – saving the time and costly expense of frequently exchanging membranes.
Requires virtually no maintenance
The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled.
Fast, stable, and accurate results
IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability. And the solid-state sensor design doesn’t allow the membrane to flex or undergo surface area changes, leading to more stability in results over a variety of samples.
Ultimate traceability in measurement history
Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
Can be moved between meters without the need to re-calibrate or re-enter measurement settings
Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters
Specifications
Technical Attributes
Accuracy | ±0.02 mV or 0.05%, whichever is greater |
Cable Length | 1 m (3.28 ft) |
Electrode Type | Non-Refillable Dritek Gel Reference Element |
ISA Required | Ammonium ISA (#2980699) |
Junction | Double Junction (ceramic Porous Pin and annular porous PTFE) |
Kit? | Yes |
Length | 175 mm (6.89 in.) |
Method Type | Laboratory: Non-Refillable Dritek Gel Reference Element |
Parameter | Ammonium |
Probe Type | Standard |
Product Kit | Model: ISENH4181 Accessories Included: Calibration Reagents Pack |
Range | 0.018 mg/L (10-6 M) - 9 g/L (0.5 M) NH4-N |
Reference Type | Ag/AgCl |
Resolution | Selectable up to 4 significant digits |
Sample depth | 25.4 mm (1 in.) |
Sample Volume | 15 mL |
Sensor material | Epoxy |
Sensor Type | Solid-state PVC membrane |
Special Features | Dry storage & fast response time. No replacement membranes. |
Temperature Accuracy | ±0.3 °C (±0.54 °F) |
Temperature Range | 0 - 50 °C (32 - 122 °F) |
Temperature Resolution | 0.1 °C (0.18 °F) |
Test requirements | Parameter Needed: Ammonium Minimum Sample Depth (mm): 26 |
Thermistor | ATC |
Warranty | 6 months |
Weight | 0.15 kg |
What's included? | Kit includes IntelliCAL ISENH4181 combination ammonium ISE, 1m cable (no. ISENH418101), Hach ammonia nitrogen standard solutions, 500 mL bottles of 10 mg/L (no. 15349) and 10 mg/L (no. 2406549), Pack of 100 Hach ammonium ionic strength adjustor (ISA) Powder Pillows (no. 2980699), and ISE Basic User Manual. |