HACH
HACH IntelliCAL ISECL18101 Chloride (Cl⁻) Ion Selective Electrode (ISE) with Calibration Reagents Pack PN. ISECL181AP
HACH IntelliCAL ISECL18101 Chloride (Cl⁻) Ion Selective Electrode (ISE) with Calibration Reagents Pack PN. ISECL181AP
无法加载取货服务可用情况
* Please consult before ordering
The IntelliCALⓇ Chloride ISE Analysis Package contains all you need to start measuring chloride (Cl-) with your HQD meter instrument: The IntelliCALⓇ ISECL181 Chloride ISE with 1 m cable, 1 L bottles of 100 mg/L and 500mL of 1000 mg/L of Hach Chloride standard solutions, pack of 100 Hach chloride ionic strength adjustor (ISA) Powder Pillows.
Benefits
Requires virtually no maintenance
The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled or membrane replacement.
Fast, stable, and accurate results
IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.
Ultimate traceability in measurement history
Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
Can be moved between meters without the need to re-calibrate or re-enter measurement settings
Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters
Specifications
Technical Attributes
Accuracy | ±0.02 mV or 0.05%, whichever is greater |
Cable Length | 1 m (3.28 ft) |
Electrode Type | Non-Refillable Dritek Gel Reference Element |
ISA Required | Chloride ISA (#2318069) |
Junction | Double Junction (ceramic Porous Pin and annular porous PTFE) |
Kit? | Yes |
Length | 175 mm (6.89 in.) |
Method Type | Laboratory: Non-Refillable Dritek Gel Reference Element |
Parameter | Chloride |
Probe Type | Standard |
Product Kit | Model: ISEF121 Accessories Included: Calibration Reagents Pack |
Range | 0.1 mg/L (3 x 10-6 M) - 35.5 g/L (1 M) Cl⁻ |
Reference Type | Ag/AgCl |
Resolution | Selectable up to 4 significant digits |
Sample depth | 25.4 mm (1 in.) |
Sample Volume | 25 mL |
Sensor material | Epoxy |
Sensor Type | Solid-state crystal membrane |
Special Features | Dry storage & fast response time. No replacement membranes. |
Temperature Accuracy | ±0.3 °C (±0.54 °F) |
Temperature Range | 5 - 50 °C (41 - 122 °F) |
Temperature Resolution | 0.1 °C (0.18 °F) |
Test requirements | Parameter Needed: Chloride Minimum Sample Depth (mm): 26 |
Thermistor | ATC |
Warranty | 6 months |
Weight | 0.15 kg |
What's included? | Kit includes IntelliCAL ISECL181 combination chloride ISE, 1m cable (no. ISECL18101), Hach chloride standard solutions: 1 L bottle of 100 mg/L (no. 2370853) and 500 mL of 1000 mg/L (no. 18349), a pack of 100 Hach chloride ionic strength adjustor (ISA) Powder Pillows (no. 2318069), and ISE Basic User Manual. |
Share