跳至产品信息
1 / 1

HACH

HACH IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 3 m cable PN. ISECL18103

HACH IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 3 m cable PN. ISECL18103

常规价格 ¥10,895.30 CNY
常规价格 ¥12,818.00 CNY 促销价 ¥10,895.30 CNY
促销 售罄

* Please consult before ordering

IntelliCAL ISECL181 is a digital, combination, Chloride ion selective electrode (ISE) with a with a non-refillable gel driTEK reference with a double junction, ceramic porous pin and porous PTFE annular ring, and built-in temperature sensor. The electrode measures Chloride concentration in water samples. The laboratory version of this ISE is shockproff with its Epoxy plastic body.The IntelliCAL ISECL181 probe is available with a 1 or 3 meter cable and is intended for laboratory use. The ISECL181’s solid-state sensor design eliminates membrane replacement and allows for dry storage of the ISE. The ISECL181 is ideal for measuring chloride concentrations in wastewater, drinking water and general water quality applications.

Benefits

Requires virtually no maintenance

The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled or membrane replacement.

Fast, stable, and accurate results

IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.

Ultimate traceability in measurement history

Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number

Can be moved between meters without the need to re-calibrate or re-enter measurement settings

Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters

Specifications

 

Technical Attributes

Accuracy ±0.02 mV or 0.05%, whichever is greater
Cable Length 3 m (9.84 ft)
Electrode Type Non-Refillable Dritek Gel Reference Element
ISA Required Chloride ISA
(#2318069)
Junction Double Junction (ceramic Porous Pin and annular porous PTFE)
Kit? No
Length 175 mm (6.89 in.)
Method Type Field: Non-Refillable Dritek Gel Reference Element
Parameter Chloride
Probe Type Standard
Product Kit Model: ISECL181
Accessories Included: None
Range 0.1 mg/L (3 x 10-6 M) - 35.5 g/L (1 M) Cl⁻
Reference Type Ag/AgCl
Resolution Selectable up to 4 significant digits
Sample depth 25.4 mm (1 in.)
Sample Volume 25 mL
Sensor material Epoxy
Sensor Type Solid-state crystal membrane
Special Features Dry storage & fast response time. No replacement membranes.
Temperature Accuracy ±0.3 °C (±0.54 °F)
Temperature Range 5 - 50 °C (41 - 122 °F)
Temperature Resolution 0.1 °C (0.18 °F)
Test requirements Parameter Needed: Chloride
Minimum Sample Depth (mm): 26
Thermistor ATC
Warranty 6 months
Weight 0.15 kg
What's included? IntelliCAL ISECL181 combination Chloride ISE, 3 m cable (ISECL18101), Test certificate, and Basic User Manual.
查看完整详细信息