HACH
HACH IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 3 m cable PN. ISECL18103
HACH IntelliCAL ISECL181 Chloride (Cl⁻) Ion Selective Electrode (ISE), 3 m cable PN. ISECL18103
无法加载取货服务可用情况
* Please consult before ordering
IntelliCALⓇ ISECL181 is a digital, combination, Chloride ion selective electrode (ISE) with a with a non-refillable gel driTEK reference with a double junction, ceramic porous pin and porous PTFE annular ring, and built-in temperature sensor. The electrode measures Chloride concentration in water samples. The laboratory version of this ISE is shockproff with its Epoxy plastic body.The IntelliCAL ISECL181 probe is available with a 1 or 3 meter cable and is intended for laboratory use. The ISECL181’s solid-state sensor design eliminates membrane replacement and allows for dry storage of the ISE. The ISECL181 is ideal for measuring chloride concentrations in wastewater, drinking water and general water quality applications.
Benefits
Requires virtually no maintenance
The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled or membrane replacement.
Fast, stable, and accurate results
IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.
Ultimate traceability in measurement history
Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
Can be moved between meters without the need to re-calibrate or re-enter measurement settings
Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters
Specifications
Technical Attributes
Accuracy | ±0.02 mV or 0.05%, whichever is greater |
Cable Length | 3 m (9.84 ft) |
Electrode Type | Non-Refillable Dritek Gel Reference Element |
ISA Required | Chloride ISA (#2318069) |
Junction | Double Junction (ceramic Porous Pin and annular porous PTFE) |
Kit? | No |
Length | 175 mm (6.89 in.) |
Method Type | Field: Non-Refillable Dritek Gel Reference Element |
Parameter | Chloride |
Probe Type | Standard |
Product Kit | Model: ISECL181 Accessories Included: None |
Range | 0.1 mg/L (3 x 10-6 M) - 35.5 g/L (1 M) Cl⁻ |
Reference Type | Ag/AgCl |
Resolution | Selectable up to 4 significant digits |
Sample depth | 25.4 mm (1 in.) |
Sample Volume | 25 mL |
Sensor material | Epoxy |
Sensor Type | Solid-state crystal membrane |
Special Features | Dry storage & fast response time. No replacement membranes. |
Temperature Accuracy | ±0.3 °C (±0.54 °F) |
Temperature Range | 5 - 50 °C (41 - 122 °F) |
Temperature Resolution | 0.1 °C (0.18 °F) |
Test requirements | Parameter Needed: Chloride Minimum Sample Depth (mm): 26 |
Thermistor | ATC |
Warranty | 6 months |
Weight | 0.15 kg |
What's included? | IntelliCAL ISECL181 combination Chloride ISE, 3 m cable (ISECL18101), Test certificate, and Basic User Manual. |
Share