A robust and portable single channel Dissolved Oxygen meter designed for field use with simple USB data transfer capabilities
The HQ1130 Portable Dissolved Oxygen Meter is designed for water quality professionals who need to perform dissolved oxygen analysis in either field and lab environments. This new portable Dissolved Oxygen meter allows you to collect accurate measurements, manage data, and easily review results, and with its IP67-rated ruggedness, it can withstand field use.
The HQ portable line of electochemistry meters provide a true rugged, field-ready solution with on-screen step-by-step operating instructions that provides users with confidence in their results. Unlike other field meters with basic user interfaces and less accessible data management, HQ meters secure, simplify, and accelerate the entire measurement process from calibration to data entry for field users.
Alternatively the HQ Series of meters offers varying features. The HQ4000 Series offers three multiparameter probe-inputs and larger, color displays, the HQ2000 Series offers two multiparameter probe-inputs, and the HQ1000 Series offers a single probe-input . These meters offer a range of measurement versatility - eliminating the need for multiple instruments.
Benefits
Performing a successful calibration has never been so simple
Most measuring issues are due to incorrect calibration procedures. With our illustrated, step-by-step on-screen calibration and troubleshooting procedures, water quality professionals can succeed every time.
Deliver your daily activity in just a few clicks
Whether you are at your facility or working in the field, the Hach® HQ Series portable meter ensures your data will be safely transferred via USB.
Sensors designed for every application
We offer standard laboratory and rugged field IntelliCALⓇ smart sensors available with the HQ Series to measure a wide variety of parameters including Total Dissolved Solids (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Temperature, Conductivity, and pH. IntelliCAL smart probes are automatically recognized by HQ meters, retain calibration history and method settings to minimize errors and setup time. They incorporate proven technology to deliver superior accuracy and response times – even when measuring challenging samples or challenging operating environments.
Peace of mind: Hach service and support will be there for you
Our Technical Support, Field Service, and Central Service Teams work together with over 80 years of electrochemistry expertise to help you maximize instrument uptime, ensure data integrity, maintain operational stability, and reduce compliance risk. Never feel alone when you need support.
Specifications
Technical Attributes
Accessories Included | USB charger, power cable, and clips |
Automatic Buffer Recognition | Yes |
Backlight | Yes |
Barometric Pressure Measurement | Automatic compensation of DO when using an LDO or LBOD probe |
Calibration Intervals/Alerts/Reminder | Off, selectable from 2 hours to 7 days |
Certifications | CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS |
Data Export | USB connection to PC or USB storage device (limited to the storage device capacity). |
Data Memory | 5000 data points |
Data Storage | Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode. |
Dimensions (H x W x D) | 63 mm x 97 mm x 220 mm |
Display | Up to 3 parameters at a time, dependent on HQ model |
Display Type | 536x336 Mono-TFT |
DO Measurement Range | 0.1 - 20.0 mg/L (ppm), 1 - 200% saturation |
DO Resolution | 0.1 |
Enclosure Rating | IP67 (with battery compartment installed) |
GLP Features | Date; Time; Sample ID; Operator ID, Calibration |
Inputs | 1 |
Instrument | Portable |
ISE Direct Measurement Range | No |
ISE Electrode Calibration | No |
Kit? | Meter only |
Languages | English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian |
Lock Function | Continuous / Auto-stabilization ("press to read") / At Interval |
Measurement Method | Probe specific programmed method settings |
Model | HQ1130 DO/1 Channel |
mV Measurement at Stable Reading | No |
mV Measurement Range | No |
Operating Error Messages | Clear text error messages displayed |
Operating Humidity | 90% (non-condensing) |
Operating Interface | Soft Touch Keypad |
Operating Temperature | 0 - 60 °C |
Parameter | Dissolved Oxygen (DO) |
Power Supply | Rechargeable lithium-ion battery 18650 (internal) Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external) |
Probe Type | Intellical Standard Laboratory or Rugged Field |
Probes included | None |
Protection Class | IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external |
Sensor A | None |
Sensor B | None |
Sensor C | None |
Storage Conditions | -20 - 60 °C, max. 90% relative humidity (non-condensing) |
Temperature Compensation | Automatic Temperature compensation for pH |
Temperature Measurement | °C or °F |
Temperature Resolution | 0.1 °C |
Type of measurement | Field Measurements |
Warranty | 12 months |
Weight | 519 g (Meter only) |
What's included? | HQ1130 Portable DO Meter, 1 channel, includes manuals, Li-Ion batteries, USB charger with cable for US |