跳至产品信息
1 / 4

HACH

HACH AT1000 Potentiometric Titrator with 1 Burette and 2 Pumps - Model AT1122 PN.AT1122.97

HACH AT1000 Potentiometric Titrator with 1 Burette and 2 Pumps - Model AT1122 PN.AT1122.97

常规价格 ¥40,521.60 CNY
常规价格 ¥50,652.00 CNY 促销价 ¥40,521.60 CNY
促销 售罄

Automatic titration without all the costs and complications

Simplify complex titration with the Titralab AT1000 from Hach. Straight from the box the AT1000 eliminates operator interpretation and manual processes you have come to expect with existing manual titration. The automatic system gives you more reliable results without complicated analysis. To make setup and titration simple, the AT1000 utilizes application specific kits to make it quick and easy for anyone to set up and operate a test.

The AT1122 instrument can be used with the following Hach Application Packs:
- Free & Total Chlorine, Chlorine Dioxide, Chlorite, Sulfite (AP0007.AT1122)
This application pack is designed to replace the Autocat 9000 Chlorine Amperometric Titrator
- Free & Total SO₂ in wine (AP0012.AT1122)
- The AT1122 can also run any applications listed for the AT1102 and AT1112

Benefits

Accurate and Reliable Titration Results

• Eliminates errors in manual processes and operator interpretation
• Pre-programmed titration methods automatically detect endpoints and perform calculations
• High resolution electronic burette with 20,000 steps
• Automatic sample preparation using embedded peristaltic pumps
• High performance probes for reliable measurements

Easy to Use for all Operators

• Press one button to get the correct result
• Operators of all skill levels can get accurate measurements
• No need for custom programming with Hach’s unique application specific routines
• Simple user interface with large color display that shows the titration curve as it is measuring
• USB ports to quickly and easily capture data to a PC and attach optional keyboard/mouse or printer

Low Cost of Ownership

• Reduces the amount of reagent used for every titration cutting cost of ownership month after month
• Increases lab throughput by allowing operator to prepare next sample while titrator performs measurement
• Adding an AS1000 sample changer allows the operator to load multiple samples and come back for results later

Improves Lab Safety

• Minimizes direct contact with reagents
• No need for potentially dangerous colored indicators
• Instrument can be easy and safely moved thanks to the compact design

Low Maintenance

• Reliable design significantly reduces downtime
• Extended periods between maintenance routines
• Maintenance is simple and easy to perform

Specifications

 

Burette

Volumes Available 2.5/5/10/25 mL, ISO8655-3
 

Technical Attributes

Application Maximum number of applications: 5
Automatic Reagent Addition(s) Integrated peristaltic pumps for reagent addition
Beaker Volumes Accepted System specific beakers: Polypropylene, 50 mL & 150 mL with clips
Generic beakers supported: Up to 250 mL low form glass
Burette 1
Burette Motor Resolution 20,000 steps with electronic µstepping technology (128 µsteps/step)
Calibration Titrant & electrode (up to 5 buffers in Auto Mode, fixed & user defined)
Calibration Curves Display Direct & derivative titration curves, electrode calibration curve
Calibration Intervals/Alerts/Reminder Yes, user defined period
Certifications Safety IEC/EN 61010-1; EMC IEC/EN 61326-1
Data Export On USB Key, CSV type, Excel compatible.
Data Memory Last 100 samples, QC & blank analyses, last 10 calibrations
Data Storage Date, Time, Operator IDs, Sample IDs
Display Type 5,7"; Graphic colour; VGA
Electrode IntelliCAL ("Plug & Play" digital), analog, photocolorimetric; 2 inputs available
Embedded Procedures Tubing bubble purging, reagent priming, burette and pump replacement
Installation Category Category II
Languages English, German, French, Italian, Spanish
Maintenance Scheduler Yes, user defined
Material Enclosures PP Latene, Silicone, Hardered Glass, POM, Stainless steel. Splashproof design
Measurement Method Potentiometric (zero & imposed current), amperometric, colorimetric
Measurement Modes End Point, Inflection Point - Sample, Blank, Sample with Blank, QC Sample, QC Sample with Blank
Model AT1122
Operating Conditions 15 - 35 °C (59 - 95 °F), 20 - 80 % RH, non-condensing
Operating Humidity 20 - 80 % (non-condensing)
Operating Interface Soft keypad (silicone)
Operating Temperature Range 15 - 35 °C (59 - 95 °F)
Outputs Electrode ports (x2), USB (x2), Serial (x1), Ethernet (x1)
Parameter mV/pH, Conductivity, Temperature (°C or °F)
Password Protection Yes, user defined
Pollution Degree 2
Power Requirements (Hz) 50/60 Hz
Power Requirements (Voltage) 100/240 VAC
Pump flow rate 100 mL/min
Pumps 2
Required Application Package/s AP0007.AT1122 Free & Total Chlorine, Chlorine Dioxide, Chlorite, & Sulfite (Autocat)
AP0012.AT1122 Free & Total SO₂ in wine
Resolution mV/pH: ±0.1 mV / ±0.001 pH|Conductivity: ±0.5 % of reading|Temperature: ±0.3 °C
Sample Stand Integrated, magnetic stirring, beakers up to 250 mL
Storage Conditions -5 to 40 °C (23 to 104°F)
Supported Peripherals Printer, PC software, balance, sample changer, keyboard, mouse, barcode reader, sampling pump, propeller stirrer
Titration Modes Sample, blank, sample with blank, QC sample, QC sample with blank
Titration Types Potentiometric (zero & imposed current), amperometric, colorimetric
Warranty 12 months
Weight 4 kg
What's included? Hach AT1122 Instrument, Tube Holder, Sensor Storage Tubes, Power Supply, Power Cord, Manual

Sold Separately: Don't forget to order your Application Pack and Reagents and consider purchasing a Sample Changer!
查看完整详细信息